Applying Hyworks Client Upgrade Patch:


Login into Hyworks management console. Go to Device Tab and click on Registered device for Hardware Version.


Login into Hyworks Controller server and copy the Hyworks Upgrade Patch to below given location.


C:\Program Files (x86)\Accops\HyWorks Controller\Service\Contents\Firmware\upgrade\


If Hardware version is 

a) ETCC00XC0480


Go to C:\Program Files (x86)\Accops\HyWorks Controller\Service\Contents\Firmware\ETCC00XC0480 and edit info file.

FileName=<Name of New upgrade patch> eg., HyWorksClient_Installer_UPGRADE_255180_HY3000.7z

Version=<Increase the existing version number by 1>



b)ETCC00XC0620

  

Go to C:\Program Files (x86)\Accops\HyWorks Controller\Service\Contents\Firmware\ETCC00XC0620 and edit info file.

FileName=<Name of New upgrade patch> eg.,HyWorksClient_Installer_UPGRADE_255180_HY3000.7z

Version=<Increase the existing version number by 1>


Login into Hyworks management console and Enable Auto-update on device. (Refer Page No.13).




Let us know on support.accops.com for any issues.